Prices are in US dollars, plus tax where it applies. Stripe, our payment processor and the seller of record, adds tax at checkout.
All sales are final. If something is really wrong, such as a duplicate charge or a purchase that does not unlock what you bought, write to support@tradeexampro.com and we will put it right.
One-time payment. Nothing renews.
You have an exam ticket for this practice test. Start the mock exam to use it.
Question count, time limit and pass mark differ by where you take it. Check the official candidate bulletin from the organisation that runs your exam.
Sample questions
A physical Emergency Stop pushbutton is wired normally closed (NC) to PLC input I:0/1. To make a rung stay true while the E-Stop is NOT pressed and drop out if the button is pressed or the wire breaks, which instruction should be placed in series on the rung?
An XIO instruction addressed to I:0/1
An XIC instruction addressed to I:0/1
An OTL latch instruction addressed to I:0/1
An OTE coil instruction addressed to I:0/1
Show the answer
B. An XIC instruction addressed to I:0/1
Because the NC contact holds input I:0/1 at 1 during normal operation, an XIC instruction evaluates true while healthy and turns false if the button opens or the wire breaks (fail-safe). Using XIO would invert the logic and allow operation on a broken wire.
Reference: NFPA 79 Chapter 9 (Control Circuits and Control Functions)
A double-acting pneumatic cylinder extends too quickly and slams into its end cap. Where should a meter-out flow control valve be installed to smooth the extension stroke?
On the air supply port feeding the cap end, restricting the air coming into the cylinder as it extends
On the rod-end exhaust port, restricting air leaving the cylinder during extension
Upstream of the FRL filter to lower main header pressure
Between the compressor tank and the main isolation ball valve
Show the answer
B. On the rod-end exhaust port, restricting air leaving the cylinder during extension
Meter-out flow control restricts exhaust air leaving the cylinder rather than incoming supply air. Because air is compressible, trapping backpressure on the exhaust side prevents jerky slip-stick motion and cushions the load.
Reference: ISO 4414 Section 5.3 (Pneumatic Actuators and Speed Control)
In a standard 3-wire motor start-stop seal-in rung, what happens if the momentary Start button is released after the motor output coil energizes?
The motor stops at once and stays off until the Start button is pressed and held again
The PLC enters fault mode due to a parallel branch
A parallel contact tied to the output coil keeps the rung energized
The Stop contact automatically latches into a closed state
Show the answer
C. A parallel contact tied to the output coil keeps the rung energized
The seal-in (holding) contact in parallel with the Start contact is addressed to the motor output coil itself. Once energized, it maintains power flow around the released Start button until the Stop contact or overload opens the rung.