Amazon RME and Ramsay MultiCraft maintenance technician practice test

100 practice questions for this exam, each with the reason for the answer and its reference.

Start practising

Mechatronics, PLC & RME: practice test

10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.

Timed mock exam

50 questions in 60 minutes, drawn from every topic. No answers shown until the end, then a score, your weakest topics and a review of what you missed.

Practice tests that prepare you for this exam

Practise by topic

About the exam

Who runs it
Amazon RME, Ramsay
Where
United States

Question count, time limit and pass mark differ by where you take it. Check the official candidate bulletin from the organisation that runs your exam.

Sample questions

A physical Emergency Stop pushbutton is wired normally closed (NC) to PLC input I:0/1. To make a rung stay true while the E-Stop is NOT pressed and drop out if the button is pressed or the wire breaks, which instruction should be placed in series on the rung?

  1. An XIO instruction addressed to I:0/1
  2. An XIC instruction addressed to I:0/1
  3. An OTL latch instruction addressed to I:0/1
  4. An OTE coil instruction addressed to I:0/1
Show the answer

B. An XIC instruction addressed to I:0/1

Because the NC contact holds input I:0/1 at 1 during normal operation, an XIC instruction evaluates true while healthy and turns false if the button opens or the wire breaks (fail-safe). Using XIO would invert the logic and allow operation on a broken wire.

Reference: NFPA 79 Chapter 9 (Control Circuits and Control Functions)

A pry bar lifts a 300-pound crate. The crate is 2 feet from the pivot and you push down 6 feet from the pivot. Ignoring the bar's weight, how hard must you push?

  1. 900 pounds
  2. 150 pounds
  3. 100 pounds
  4. 50 pounds
Show the answer

C. 100 pounds

Turning effect must balance: 300 × 2 = 600, and 600 ÷ 6 = 100 pounds. The longer your side of the bar, the less force you need.

Reference: Simple machines: levers

A double-acting pneumatic cylinder extends too quickly and slams into its end cap. Where should a meter-out flow control valve be installed to smooth the extension stroke?

  1. On the air supply port feeding the cap end, restricting the air coming into the cylinder as it extends
  2. On the rod-end exhaust port, restricting air leaving the cylinder during extension
  3. Upstream of the FRL filter to lower main header pressure
  4. Between the compressor tank and the main isolation ball valve
Show the answer

B. On the rod-end exhaust port, restricting air leaving the cylinder during extension

Meter-out flow control restricts exhaust air leaving the cylinder rather than incoming supply air. Because air is compressible, trapping backpressure on the exhaust side prevents jerky slip-stick motion and cushions the load.

Reference: ISO 4414 Section 5.3 (Pneumatic Actuators and Speed Control)